The Westfield Fire Department will now require all third-party inspection testing and maintenance reports and forms to be submitted to Brycer for fire protection and life safety compliance review and timely submitting deadlines. Examples of the types of reports that must be submitted are fire protection systems' maintenance tests and repairs. The list of the exact systems requiring submission of reports can be found listed below.
Please visit this website for more information and to register.
Letters will be mailed soon to area owners, inspectors and technicians with more information regarding this new compliance program.
This program will begin accepting submissions on July 15, 2025.
| Report Type | 6-Month | Annual | 5-Year | Form/Standard |
|---|---|---|---|---|
| Air Sampling System | 527 CMR 1.00, 10.24.1 | |||
| Automatic Closing Fire Assemblies | 527 CMR 1.00, 12.4.2.8.4.1 | |||
| Chemical Storage Room | 527 CMR 1.00; 10.24.1, NFPA 45; 7.14.1, NFPA 45; 9.3.4.6 | |||
| Clean Agent | 527 CMR 1.00; 10.24.1, NFPA 2001; 11.3 & 11.4, NFPA 12A; 6.1.1 | |||
| Emergency Power Battery/Unit Lighting | 527 CMR 1.00; 14.13.2.1.1 | |||
| Emergency Power Generator | 527 CMR 1.00, 11.7.5.1 | |||
| Emergency Responder Radio Coverage System | 527 CMR 1.00, 11.12.2 to NFPA 72, 24.9.2 to NFPA 1221 11.3.9.2.7 | |||
| Fire Alarm System | X | 527 CMR 1.00 13.10.3.2.4 & 13.10.6.4 to NFPA 72, 7.7.1.2 | ||
| Fire Escape | X | 527 CMR 1.00, 14.4.1 & IFC 1104.16.5.1 | ||
| Fire Extinguishers | X | 527 CMR 1.00: 13.6.4.1.1 & NFPA 10: 7.3.1.1 | ||
| Fire Hydrant, Private | X | 527 CMR 1.00, 10.24.1 to NFPA 24; 14.1 to NFPA 25; 7.1.1.2 | ||
| Fire Pump | 527 CMR 1.00 13.4.4 to NFPA 25, 4.3.1.2 & 4.3.3 | |||
| Foam System | X | 527 CMR 1.00, 10.24.1 | ||
| Gas Detection System | NFPA 2; 6.13.2 | |||
| Hood Suppression System | X | 527 CMR 1.00, 50.6.2.8 & 50.6.2.8.1 | ||
| Leak Detection | 527 CMR 1.00, 42.5.4.2.2 | |||
| Paint/Spray Booth Suppression | 527 CMR 1.00, 66.6.9.1 and NFPA 25, 12.2.1.1 | |||
| Pressure Reducing Valves (PRV's) | 527 CMR 1.00; 13.2.3.3, NFPA 25; 12.5.2.1 | |||
| Rental Property Inspection | ||||
| Rescue Air System | ||||
| Smoke Management Systems | X | X | 527 CMR 1.00; 11.8.2 to NFPA 92; 8.6, 8.6.1.1 OR 8.6.1.2 | |
| Sprinkler System (Dry & Wet) | X | X | 527 CMR 1.00 [NFPA 25] 13.3.3.4.3.3 [25:4.3.3] & 13.3.3.4.3.1.2 [25:4.3.1.2] | |
| Standpipe | X | X | 527 CMR 1.00 13.2.3.3 to NFPA 25, 4.3.1.2 & 4.3.3 | |
| Suppression System, Special | NFPA 17 (2021) | |||
| Water Monitor | ||||
| Water Tank | 527 CMR 1.00, 10.24.1 to NFPA 24; 14.1 to NFPA 25; 9.1.1.2 |
| Commercial Cooking Hood Cleaning: 527 CMR 1.00, 50.6.6.15 |
30 Days | 90 Days | Semi-Annually | Annual |
|---|---|---|---|---|
| Solid Fuel | X |
|||
| High Volume Cooking Operations (ie. 24 hour cooking, charbroiling & wok cooking) |
X |
|||
| Moderate Volume Cooking Operations | X |
|||
| Low Volume Cooking Operations (ie. churches, day camps, seasonal businesses & senior centers.) |
X |
Inspectors and technicians conducting inspections, maintenance, repair services and installing fire protection and life safety systems are required to utilize this new third-party reporting system for properties within the City of Westfield. The Compliance Engine/Brycer can provide complimentary assistance with the registration process and training for their website on how to submit.
Responsible parties are defined as:
- Property Owners, or
- Individuals or companies delegated in writing by the property owner to be responsible for the upkeep of a fire protection or life safety systems.
This program will not impact a building owner's ability to select a qualified contractor, as required by the Massachusetts Fire Prevention Code. Property owners will be able to establish their own account with The Compliance Engine to access reports and monitor the systems inspected for their property with no cost. This feature will not be available until after July 15, 2025.
Report Fees
The fee for the submittal of a report is $20 per report. This fee is charged through the website to an individual or company submitting the report. The City of Westfield does not receive any of the money collected for this reporting system. The fees belong to the website system operator for maintenance and upkeep of their website conducting the submittal process.
Portable fire extinguishers have a different fee schedule. The fee schedule for portable fire extinguishers is as follows:
- 1 to 5 Extinguishers = $15
- 6+ Extinguishers = $20
Late fees
Late fees for the submittal reports will be added to the report fee cost depending on the length of time of receipt after the inspection date. Specifically, reports submitted after 30 days from the inspection date will incur a $10 late fee. Reports submitted after 60 days from the inspection date will incur a $20 late fee.
Correction Reports
In the case of deficiencies reported on an inspection report, additional fees will not be charged to upload the correction reports when submitted under the original inspection submittal.
This page is under construction. Information coming soon. Please check back here before or on July 15, 2025.